In the logistics and transportation process of industrial production, forklifts play an indispensable role. As the power source of forklifts, the performance status of forklift lead-acid batteries directly affects the operational efficiency, service life and usage safety of forklifts. A scientific and reasonable charging method is the key to maintaining the good performance of the battery. However, in actual operation, many people have misunderstandings about the charging knowledge of lead-acid batteries for forklifts or operate them improperly, which leads to problems such as shortened battery life and frequent malfunctions. For this reason, this article will provide a detailed introduction to the scientific charging methods of lead-acid batteries for forklifts, offering practical guidelines for relevant operators.
Preparations before charging
The preparatory work before charging is the first step to ensure scientific charging, which directly affects the charging effect and battery safety, and must be taken seriously.
First of all, a comprehensive inspection of the battery's appearance should be carried out. Carefully observe whether the battery casing has any damage, cracks or deformations, etc. If the casing is found to be damaged, the electrolyte may leak, which not only affects the battery performance but also may cause corrosion and safety hazards. At this time, use should be stopped immediately and maintenance or replacement should be carried out. Charging must not continue. At the same time, check whether there is any corrosion on the battery terminals. If there is white or green corrosion, rinse them clean with hot water and then dry them with a dry cloth to ensure good conductivity.
Secondly, check whether the connecting wires are firm. Check whether the connection wires between the battery and the charger, as well as the connection wires between individual cells inside the battery, are loose, broken or have poor contact. Loose connection wires can cause an increase in contact resistance during charging, leading to overheating, affecting charging efficiency, and even potentially causing a fire. Once loose connecting wires are found, they should be tightened in time. If there is any breakage or damage, new connecting wires need to be replaced.
In addition, the liquid level of the electrolyte should be checked. For maintainable lead-acid batteries, the electrolyte level must be maintained within the specified range, that is, 10 to 15 millimeters above the plates. If the liquid level is too low, it will cause the plates to be exposed to the air, accelerating the oxidation and sulfidation of the plates and shortening the battery life. If the liquid level is too high, the electrolyte will expand and overflow due to heat during charging, corroding the battery casing and surrounding components. When the liquid level is insufficient, distilled water should be added to replenish it. It is important to note that tap water or electrolyte must never be added. Tap water contains impurities that can contaminate the electrolyte and affect battery performance, while electrolyte can alter the concentration ratio inside the battery and cause damage to it.
Finally, ensure that the charging environment meets the requirements. The charging location should be well-ventilated. During the battery charging process, a mixture of hydrogen and oxygen is produced. Poor ventilation may cause gas accumulation, which can easily lead to an explosion when exposed to open flames. At the same time, the charging environment should be kept away from fire sources, heat sources and spark sources. The temperature should be controlled at around 25℃. Both excessively high and low temperatures will affect the charging effect and battery life.
Key points of operation during the charging process
During the charging process, strictly following the correct operation points is the core link to ensure the quality and safety of charging.
First, connect the charger to the battery correctly. When connecting, first connect the output terminal of the charger to the positive and negative terminals of the battery. Be careful not to reverse the positive and negative terminals, otherwise the charger and the battery will be damaged. After the connection is completed, turn on the input end of the charger to the power supply. During the connection process, make sure that the plug is tightly connected to the socket and the terminal post to avoid generating sparks.
Secondly, select the appropriate charging parameters. The charging parameters of lead-acid batteries for forklifts of different models and capacities vary. It is necessary to select the matching charger and charging parameters in accordance with the instructions provided by the battery manufacturer. Generally speaking, for batteries that have been charged for the first time or deeply discharged, a slow charging method should be adopted, with the charging current being about 10% of the battery capacity. For daily supplementary charging, the conventional charging current can be used. If the charging current is too large, it will cause intense reactions inside the battery, generate a large amount of heat, raise the temperature of the electrolyte, accelerate the corrosion and shedding of the plates, and shorten the battery life. If the charging current is too small, it will prolong the charging time and may lead to insufficient battery charging.
At the same time, the charging time should be well controlled. Under normal circumstances, when the terminal voltage of the battery reaches the specified value and the electrolyte starts to bubble vigorously, it indicates that the battery is basically fully charged. At this point, charging should be stopped promptly. Overcharging can cause a large amount of gas to be generated inside the battery, leading to significant loss of electrolyte and excessive corrosion of the plates, which seriously affects the battery's performance and lifespan. The charging time varies for batteries of different capacities. Operators should roughly estimate the charging time based on the battery capacity and charging current, and closely monitor the battery status during the charging process to avoid overcharging.
During the charging process, the status of the battery should be closely monitored. Regularly check the battery temperature. Under normal circumstances, the battery will slightly heat up during the charging process. If the battery temperature exceeds 45℃, stop charging immediately. Wait until the battery cools down to the normal temperature before resuming charging. At the same time, check whether the parameters of the charger are set correctly. If the parameters are abnormal, adjust them before using. In addition, it is necessary to observe the state of the electrolyte. During the charging process, the electrolyte will gradually become turbid, which is a normal phenomenon. However, if an abnormal color of the electrolyte is found, it may be that the internal plates of the battery have fallen off or short-circuited. Charging should be stopped and the battery should be inspected and repaired.
In addition, it is strictly prohibited to disassemble, strike or move the battery during the charging process. At this time, the battery is in an active state of chemical reaction inside. Disassembling or knocking it may cause the electrolyte to leak, leading to safety accidents. Moving the battery may cause the connecting wires to loosen, generating sparks and posing an explosion risk.
Finally, operators must not leave their posts without permission during the charging process. They should always be ready to deal with possible emergencies, such as battery fires and electrolyte leakage. In case of electrolyte leakage, it should be immediately covered with sand and soil to absorb the leakage and prevent the electrolyte from corroding the ground and equipment. If a battery catches fire, a dry powder fire extinguisher should be used to put it out. Do not use water to extinguish the fire, as water conducts electricity and may cause electric shock accidents.
Post-charging handling measures
After charging is completed, taking relevant handling measures can further protect the battery performance and extend its service life.
First, disconnect in the correct order. After charging is completed, the power supply at the input end of the charger should be disconnected first, and then the connection between the charger and the battery should be disconnected. This can prevent sparks from being generated when the connection is disconnected and avoid igniting the explosive gas around the battery.
Secondly, check the battery status. After charging is completed, observe whether there is any electrolyte leakage in the battery casing. If there is leakage, it should be cleaned up in time and the battery should be checked for any damage. Check if there are any signs of overheating or corrosion on the terminal posts. If so, corresponding measures should be taken. At the same time, check the electrolyte level again. If the level is too low due to the expansion and overflow of the electrolyte during the charging process, distilled water should be replenished in time.
Then, clean the battery surface and electrodes. Wipe the battery surface with a clean damp cloth to remove dust, electrolyte stains, etc., and keep the battery clean. For the electrode terminals, it is necessary to check again for any corrosion. If so, they should be cleaned thoroughly and a small amount of vaseline should be applied to prevent oxidation and corrosion of the terminals and ensure a good connection next time.
In addition, for batteries that are not in use temporarily, they should be properly stored after charging is completed. The storage location should be dry, well-ventilated and cool, avoiding direct sunlight and high-temperature environments. At the same time, it is necessary to regularly recharge the stored batteries, usually once a month, to prevent self-discharge and loss of power, and to avoid sulfation of the plates.
Frequently Asked Questions
Why does the battery get very hot during charging?
Severe battery heating during charging is usually caused by a variety of reasons. One is that the charging current is too large, exceeding the normal charging current that the battery can withstand, causing overly intense chemical reactions inside the battery and generating a large amount of heat. The second issue is that the charging time is too long. The battery is fully charged but still continues to charge, causing overcharging and generating excessive gas and heat inside. Thirdly, there is a short-circuit fault inside the battery. A short circuit will cause the current to increase sharply and generate a large amount of heat. The fourth reason is that the electrolyte level is too low, causing excessive exposure of the plates. During charging, the reaction is concentrated, resulting in local overheating.
When you find that the battery is overheating severely, you should stop charging immediately and check whether the charging current and voltage of the charger are set correctly. If the parameters are abnormal, adjust them to appropriate values. If the charging time is too long, the power supply should be disconnected in time. If there is suspicion of an internal short circuit or liquid level issue with the battery, professional personnel should be invited to carry out maintenance and handling.
What could be the reasons for a battery not charging?
Battery failure to charge is one of the common malfunctions. The possible reasons are as follows. Charger failure, such as damage to the internal circuit of the charger, abnormal output voltage or current, and inability to provide normal charging energy for the battery, requires replacement or repair of the charger at this time. Sulfation of battery plates, long-term undercharging, failure to charge in time after discharge, or battery storage for too long, etc., can all lead to the formation of sulfides on the surface of the plates, blocking the pores of the plates and preventing the battery from charging and discharging normally. In such cases, sulfation treatment of the battery is required. In severe cases, the battery may need to be replaced.
Poor contact or breakage of the connection wire can cause the charging circuit to be blocked, and the current cannot be transmitted normally. The problem can be solved by checking the connection wire and reconnecting or replacing it. Serious faults such as the detachment of internal battery plates, short circuits or damage to the separators can also cause the battery to fail to charge. In such cases, a new battery usually needs to be replaced. In addition, abnormal concentration or contamination of the electrolyte may also affect the charging effect. At this time, the electrolyte needs to be replaced.
Can batteries be charged with chargers of different models?
Do not charge the lead-acid batteries of forklifts with chargers of different models. The output voltage, current and other parameters of different models of chargers vary, and each battery has its specific charging parameter requirements. If a charger with mismatched parameters is used, when the output voltage of the charger is too high, it will cause overcharging of the battery, damage the plates and separators, and shorten the battery life. When the output voltage is too low, the battery cannot be fully charged, which affects the usage time.
If the output current of the charger is too large, it will cause the battery to heat up severely during the charging process, posing a safety hazard. If the output current is too small, it will prolong the charging time, which may lead to insufficient battery charging. At the same time, long-term low current charging will also affect the battery performance. Therefore, in order to ensure the normal charging and service life of the battery, a charger that matches the battery model must be used.
Summary
The scientific charging of lead-acid batteries for forklifts is a systematic task, involving multiple links such as the preparation before charging, the operation during the charging process, and the handling after charging. Each link is of vital importance and none can be missing. Only by strictly following scientific methods for charging operations can the service life of the battery be effectively prolonged, the stability of battery performance be guaranteed, the operational efficiency of forklifts be improved, and the risk of safety accidents be reduced at the same time.
Relevant operators should fully recognize the importance of scientific charging, master the methods and techniques of scientific charging proficiently, strictly follow the operating procedures in actual operation, and regularly maintain and service the battery. Through scientific and reasonable charging management, not only can enterprises save battery replacement costs, but also the normal operation of forklifts can be ensured, providing a strong guarantee for the smooth progress of industrial production.